QSight LC/MS/MS System | PerkinElmer
PerkinElmer
check quantity

QSight LC/MS/MS System

More than ever, laboratories analyzing food and environmental samples are faced with evolving challenges with stricter regulations demanding lower detection limits and higher levels of productivity. Lab operations need to be optimized, without any compromise on analysis confidence and accuracy.

With the PerkinElmer QSight® Triple Quad LC/MS/MS labs can test for the most challenging samples with maximized uptime and confidence. The unique dual-source configuration enables high-throughput labs to collect data in two complementary modes, maximizing the output from a single injection. Combined with the StayClean technology dramatically reduced source cleaning and maintenance, translating into higher productivity and high ROI. Running on the PerkinElmer Simplicity 3Q Software, the PerkinElmer QSight Triple Quad LC/MS/MS is easy-to-learn and use and it is a complete solution streamlining the complete workflow, from validated method development to data reporting.

Part Number
Model Name
BC003844
QSight 420 LC/MS/MS
more
BC003382
QSight 220 LC/MS/MS
more
BC003383
QSight 210 LC/MS/MS
more
BC003265
QSight 110 LC/MS/MS
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

The QSight LC/MS/MS System provides the capability and confidence required to analyze the most complex food and environmental samples. With high level of sensitivity and throughput, laboratories can meet even the most stringent regulatory requirements rapidly, easily, and effectively

  • Sensitivity for the most demanding regulations
  • Easy-to-use with ready to implement methods
  • Patented flow-based technology that enables up to 15% more productivity
  • StayClean Source, self-cleaning design for maximum sensitivity and exceptional uptime
  • Laminar Flow Ion Guide for highly efficient field-free transmission, providing virtually no maintenance requirements
  • Dual Source technology gives you the capability to set ESI or APCI modes, with two independent probes for true multiplexing
  • Modular Simplicity 3Q Software to acquire, quantify, and report with flexible data viewing options and powerful remote diagnostics.
  • Different models available (QSight 110 LC/MS/MS, QSight 210 LC/MS/MS, QSight 220 LC/MS/MS, QSight 420 LC/MS/MS) addressing different levels of performance and efficiency required by different labs’ analysis needs.

Specifications

Model Name QSight 220 LC/MS/MS
Resources, Events & More
  • All

Application Note

A Comparison Between ESI and APCI Ionisation Modes

Changing the source on many an LC/MS/MS instrument from ESI to APCI, and vice versa, involves cooling the source, manual removal and installation of the new source, followed by heating of the new source to the operating temperature, resulting in low throughput for analyses utilizing both ESI and APC ...

PDF 726 KB
A Fully Validated Method for Determination of Twelve Mycotoxins in Various Food Matrices

Mycotoxins are toxic secondary metabolites produced by various fungal species growing in foods and animal feeds. To minimize risk and protect consumers, mycotoxin levels in foods and/or feeds have been regulated by agencies in many countries around the world. A number of analytical methods for the d ...

PDF 3 MB
A Multiclass Multiresidue Method for Analysis of Veterinary Drugs in Chicken by UHPLC/MS/MS

Veterinary drugs are used in animal production to treat diseases, prevent infection and protect growth of animals, which helps provide quality marketplace. However the uncontrolled use may cause heavy human disease so regulatory agencies around the world have established maximum residue levels (MRLs ...

PDF 1 MB
Analysis of Acrylamide in Potato Chips by Isotopically Standard Addition UHPLC-MS/MS

Acrylamide is a probable carcinogen organic compound that is found in some foods that are cooked at elevated temperatures. It’s origins are due to the condensation of the amino acid asparagine and glucose as part of Maillard reaction. In 2002, Acrylamide was found to be present in french fries and b ...

PDF 1 MB
Analysis of Aflatoxins by UHPLC

Aflatoxin B1 is considered to be the most genotoxic of the mycotoxins, and, when ingested by cows, is converted to aflatoxin M1 which has been shown to cause liver cancer in certain animals.

PDF 1 MB
Analysis of Multi-Residue Pesticides in Rice by LC/MS/MS

Due to the large number of pesticides potentially used in rice production, the use of multi-residue methods capable of determining many pesticides in one single run is the most efficient approach. In this study, a fast, sensitive and selective multiresidue method has been developed for analysis of o ...

PDF 1 MB
Analysis of Per- and Polyfluoroalkyl Substances by EPA Method 8327 Using the QSight 220 UHPLC/MS/MS

Per- and polyfluoroalkyl substances (PFAS) are man-made carbon-chain based compounds that have been widely used in commercial and industrial products such as fire-fighting foams, water proofing treatments for clothing and furniture, nonstick cookware, and paper. PFAS’ are thermally and chemically st ...

PDF 1 MB
Analysis of Pork Adulterated Meat

A selective and sensitive LC/MS/MS method for fast identification and analysis of meat samples using three peptides specific for pork as biomarkers. . The optimized sample preparation procedure is easy to follow and can be used for analyzing raw, cooked and processed meat products. This method can s ...

PDF 1 MB
Analysis of Target Pesticide Residues in Berries with LC/MS/MS Coupled with a QuEChERS Sample Prep

Analysis of target pesticide residues in berries using a unique laminar flow UHPLC-ESI-MS/MS

PDF 1 MB
Analysis of Water-Soluble Vitamins in Infant Formula by UHPLC-MS MS

Water-soluble vitamins (WSV), comprised primarily of the vitamin B complex, are essential ingredients in many foods, particularly in infant formulas. When analyzing fortified foods, this can be particularly challenging due to the wide range in concentration of vitamins, in keeping with daily allowan ...

PDF 1 MB
Analysis of illegal dyes in Chili Spices via UHPLC-MS/MS

Since 2003 the usage of azo and non-azo dyes for food coloring has been declared as illegal by many of the food international authorities across the globe. That is because these substances such as Sudan I,II,III,IV and Rhodamine B, are potentially carcinogens and genotoxin in nature. As of now, no o ...

PDF 4 MB
Automated High Throughput Method for Analysis of Veterinary Drugs in Chicken by SPME-UHPLC/MS/MS

Veterinary drugs are utilized extensively in modern day farming to prevent and treat animal diseases. However, use of these drugs must be carefully monitored, and failure to regulate the presence of residual veterinary drugs in animal tissues could pose a risk to human health if animal tissues with ...

PDF 1 MB
Determination of Coumarin in Electronic Cigarette Liquids by LC/MS/MS

Coumarin (1,2-benzopyrone) occurs as a natural component in some plants, and is utilized as a flavoring ingredient in some foods, tobaccos and cosmetic products. In recent years, coumarin has been added to electronic cigarette liquid nicotine solutions as a flavoring component, producing a complex f ...

PDF 2 MB
Determination of Mycotoxins in Cereals by LC/MS/MS with Online SPE

Mycotoxins are toxic secondary metabolites produced by fungi, and are capable of causing disease and death in both humans and animals. Sample preparation is a critical step in the successful analysis of mycotoxins in food matrices. The "dilute and shoot" approach is a quick and easy way to introduce ...

PDF 3 MB
Determination of Nitrosamine Impurities in Active Pharmaceutical Ingredient (API) Using QSight 220 LC-MS/MS

Nitrosamines are a well-known group of highly potent, mutagenic impurities formed by the reaction of secondary amines with nitrite under acidic conditions. The most probable nitrosamine impurities are NDMA, NDEA, NMBA, NDBA, NDIPA, NEIPA. Following the initial observance of nitrosamine impurities in ...

PDF 448 KB
Determination of Polycyclic Aromatic Hydrocarbons in Seafood by UHPLC- MS/MS

Polycyclic aromatic hydrocarbons (PAHs) can contaminate foods during smoking, heating, and drying processes that allow combustion products to come into direct contact with food. They can also enter food supply chains through contaminated air and water, and accumulate in various food chains. Regulati ...

PDF 1 MB
Determination of Sulfonamides in milk by Ultra-Performance Liquid Chromatography coupled with Tandem Mass Spectrometry (QSight™)

Antibiotics are used in dairy cattle for different treatments, but it leads to accumulation of these residues in milk. Presence of such residues in human food can be responsible for allergic reactions, toxic effects and develops resistant strains of bacteria. To protect consumers, regulatory agencie ...

PDF 579 KB
Determination of Thirteen Beta Agonists in Pork Using UHPLC - Tandem Mass Spectrometry

Beta-adrenergic receptor agonists (ß- agonists) are synthetic drugs utilized in the treatment of conditions such as asthma in humans, and are also used as a growth-promoting agent in food-producing animals. The use of ß- agonists in food-producing livestock has been either banned or regulated across ...

PDF 1 MB
PDF 1 MB
Estimation of 136 pesticide residue in Black Pepper using QuEChERS extraction technique and QSight™ LC-MS/MS

It is very well known that Black pepper is a complex matrix that requires a proper extraction and clean-up method for interferences. In this study, a fast, sensitive and selective multi-residue method has been developed for analysis of over 136 pesticides in Pepper samples by coupling a modified QuE ...

PDF 1 MB
Free Amino Acid Analysis in Homogenized Tomato Using the QSight 220 LC/MS/MS

The free amino acid content of produce, such as tomatoes, has an impact on the nutritional value and flavor characteristics of the vegetable. In this application note, the efficient and effective transfer of a commercial laboratory's in-house method to a QSight 220 LC/MS/MS for amino acid determinat ...

PDF 1 MB
LC/MS/MS: Improved Throughput and Flexibility for Compliant Drinking Water Analysis with Dual Source Capability

Governing bodies have implemented various directives to monitor acrylamide in drinking water. This also applies in the European Union where the water framework directive and subsequent daughter directives have defined many priority substances, including acrylamide. Compounds chlorate, perchlorate an ...

PDF 1 MB
LC/MS/MS: Optimized Approach for the Analysis of Perfluoroalkyl and Polyfluoroalkyl Substances in Aqueous Samples by EPA Method 1633

Growing health concerns regarding PFAS and their prevalence in consumer goods and the environment indicate a critical need to execute existing and upcoming regulatory methods simply and reliably on commercially available instrumentation. The United States Environmental Protection Agency (EPA) has es ...

PDF 1 MB
Measurement of Cortisol & Cortisone in Urine

Simultaneous detect and quantify cortisol and cortisone in urine using the QSight 200 series mass spectrometer coupled with a commercially available kit.

PDF 615 KB
Measurement of Homovanillic Acid, Vanillylmandelic Acid & 5-HydroxyIndoleAcetic Acid in Urine

Discover a fast and reliable UHPLC-MS/MS method for the determination of HVA, VMA, and 5-HIAA acid in urine using the QSight 200 series mass spectrometer and a commercially available kit.

PDF 678 KB
Method Validation of Milk and Egg Allergens in Bakery Products by LC-MS/MS Using QSight Technology

To protect the health of allergic consumers from the inadvertent or intentional contamination by allergens, different analytical methods for the sensitive detection of allergens in food were developed over the years. In this work we present the performance of a targeted method using the QSight 220 L ...

PDF 1 MB
Multiclass-Multianalyte Method for Mycotoxin Testing in Foods Using Immunoaffinity Column Sample Clean-up with QSight LC/MS/MS

This work shows a reliable, sensitive and selective method for multi-mycotoxin determination in food samples using a PerkinElmer QSight 220 LC-MS/MS system. The method has been validated in eight different matrices and can be used in routine testing labs to meet regulatory requirements.

PDF 2 MB
Quantitation of Microcystins and Nodularin in Drinking Water Samples to Meet EPA Method 544 Requirements Using QSight LC/MS/MS

Cyanotoxins often exist intracellularly in cyanobacteria and are released into the water when cells die. Blooms caused by cyanobacteria can be harmful to the human health, animals, and the environment. Microcystin-LR (MC-LR) is one of the most common cyanotoxins and ingestion will cause negative hum ...

PDF 901 KB
Rapid Determination of Trace Amounts of Aniline and Its Derivatives by Direct Injection UHPLC/MS/MS

Aniline and aniline derivatives are widely used as raw materials and intermediates in the polymer, rubber, dye, pesticide and pharmaceutical industries. Unintended releases of aniliane or its derivatives into the environment pose a serious threat, with release possible during any stage of production ...

PDF 587 KB
Simple and Sensitive Method for Determination of Ochratoxin A in Wine by LC/ MS Using QSight Technology

Ochratoxin A (OTA) is a secondary metabolite produced by Penicillium and Aspergillus fungi species found in soil and organic matter, and is one of the most widely reported of the nearly 400 recognized mycotoxin contaminants of agricultural products. OTA can enter the human food chain through contami ...

PDF 924 KB
Simultaneous Determination of Pesticides Residues and Illegal Additives in Wine

Wine can often contain pesticides and fungicides that have been sprayed on the fruits during their growing period. In addition to these contaminants, wine can also contain additives that have been deliberately added during production processes to improve its flavor and color. In this study, a simple ...

PDF 1006 KB
Simultaneous Determination of Plant Growth Regulators in Bean Sprouts

A simple and sensitive method for the simultaneous determination of plant growth regulators

PDF 2 MB

Article

Driving Lab Efficiency and Performance Acceleration with LC/MS/MS

The COVID-19 pandemic impacted industries, economies, and lives, and brought about the need for a new approach for contract testing laboratories working in different application fields. Considering the directions shaping the laboratory industry, this article revises trends that could be also applied ...

PDF 438 KB
LC/MS/MS Basics: How It Works, Design Enhancements, and Key Applications

Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is one of the most common bioanalytical methods used today, offering ultrasensitive detection in the several-partsper- million (or even parts-per-billion) range. The unique specificity of tandem mass spectrometry provides greater flexibility ...

PDF 1 MB

Brochure

Complete Aflatoxin M1 Testing Solutions

For third party food testing labs or producers who want to conduct aflatoxin M1 analysis in dairy products, our automated aflatoxin M1 ELISA assay and QSight LC/MS/MS aflatoxin M1 analyzer provide sensitive, accurate, and fit for purpose screening and confirmative analysis solutions that you can use ...

PDF 3 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, and ...

PDF 3 MB
Enhancing Food Testing Productivity with LC/MS/MS

When it comes to analyzing food, cannabis, and environmental samples, we know it can be challenging to meet strict regulations that demand lower detection limits. We also know that throughput and efficiency are paramount in any accredited high-throughput laboratory. As a result, mass spectrometry is ...

PDF 2 MB
QSight Pesticides Analyzer Brochure

Pesticides can adversely affect human health through the food we consume but can also leach into soil and groundwater and impact us through the environment. To keep up with a complex and constantly changing regulatory environment, your pesticide analysis solution needs to keep up with your burgeonin ...

PDF 9 MB
QSight Triple Quad LCMSMS 400 Series Interactive Brochure

Our QSight triple quad LC/MS/MS family has always been known for its robust and reliable performance. But now there’s something new – something better: the high performance 400 series. Our ready-to-implement solution has the highest sensitivity and throughput the industry has ever seen and the capab ...

PDF 6 MB

Case Study

PFAS Monitoring: How One Scientist is Thinking Ahead for the Environment

Predicting the long-term impact some substances have on human health and the environment is extremely difficult and in some instances we only become aware of certain substances and chemicals’ toxic impact after they have been widely used. Recently, PFAS (per- and polyfluoroalkyl substances) have bec ...

PDF 341 KB

Ebook

What's in Your Water? PFAS Analysis Explained

Over the past decade, awareness and concern about Per- and Polyfluoroalkyl Substances (PFAS) has grown and led to more in-depth analysis of these compounds and the effects that they can have on human health. Due to their inert nature, PFASs are persistent organic pollutants and have been found to ac ...

PDF 1 MB

Flyer

PerkinElmer Wine Testing Solutions

PerkinElmer offers a complete portfolio of analytical solutions to enable fast, accurate and intuitive testing throughout the winemaking process. Whether you're testing grapes at harvest, must during fermentation, or finished wines during the bottling process, PerkinElmer helps deliver the data you ...

PDF 862 KB
QSight Triple Quad LCMSMS Series 400 Flyer

Our QSight triple quad LC/MS/MS family has always been known for its robust and reliable performance. But now there’s something new – something better: the high performance 400 series.

PDF 3 MB

Guide

Tips for Launching a Modern Cannabis Testing Lab

Demand for cannabis testing services continues to climb as more US states and countries around the globe implement regulated adult-use markets. The cannabis testing sector in the US, like many facets of the cannabis industry, is challenged by the complexity of working with a federally illegal but st ...

PDF 285 KB

Infographic

Nanometrology Portfolio Poster

This nanometrology portfolio infographic poster gives you a 1-page overview of the instrumentation required by laboratories for the investigation of nanomaterials which are used to develop advanced materials in a range of applications.

Infographic

Poster

Infographic - Solutions for your Toxicology Lab

Infographic Poster showing the range of different analytical solutions for Toxicology Labs; from GC and LC, to ICP-MS and UV-Vis. Benchtop and floor standing chromatography, spectroscopy and thermal solutions for everyday robust and reliable analyses. FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC ...

PDF 460 KB

Product Note

PDF 890 KB
QSight Simplicity 3Q Software Suite

Our modular Simplicity 3Q™ software is ideal for acquiring, quantifying and reporting

PDF 1 MB
QSight Triple Quadrupole LC/MS/MS Preparing Your Lab

Lab reequirements for QSight triple quad LC/MS/MS systems, including storage, suppleis, space, electrical, power, gas supply requirements

PDF 660 KB

Regulatory Compliance Certification

Product Certificate - QSight 210 & 220

Product Certificate for the QSight 210 & 220

PDF 159 KB

Technical Note

Flow Characteristics of a Laminar Flow Interface for LC/MS/MS

Simulation using sophisticated modeling techniques has become a powerful tool for mass spectrometry

PDF 1 MB
Theoretical Studies of Swirling Flow and Heating Methods

Theoretical Studies of Swirling Flow and Heating Methods on Droplet Evaporation in a Heated Coaxial

PDF 503 KB

Video

From Contamination to Productivity: PerkinElmer StayClean Technology

Analytical laboratories face many challenges when analyzing contaminants such as Pesticides, PFAS, mycotoxins in complex matrices. These samples often require time-consuming sample prep and regular maintenance of the analytical technology.

Video
Overcoming PFAS Challenges - Method Development for Changing PFAS Regulations

Due to PFAS persistence in the environment and potential health risks, regulations have been undergoing constant change and refinement.

Video
Overcoming PFAS Challenges – Mitigating Matrix-Induced Ion Source Contamination

PFAS matrix-induced contamination poses various challenges for analytical laboratories, from the risk of achieving low detection limits and lab downtime.

Video
Overcoming PFAS Challenges - Minimizing Sources of Contamination

PFAS compounds are ubiquitous throughout the environment and accumulate everywhere, including in the lab.

Video
Mitigate Interference and Contamination in PFAS Analysis

As per- and polyfluoroalkyl compounds become more prominent, the US Environmental Protection Agency (EPA) are developing more stringent regulations for PFAS monitoring.

Video
Efficient, Robust and reliable performance for LC/MS/MS Analysis

Stricter regulations demanding lower detection limits, increased throughput and efficiency demand that labs need an LC/MS/MS solutions that offers robust and reliable performance while ensuring efficiencies.

Video
Analyzing the Unanalyzable: Breakthrough in Complex Samples with LC/MS/MS

When examining complex compounds like PFAS, pesticides, and mycotoxins using LC/MS/MS in challenging matrices, laboratories encounter issues such as system contamination, matrix effects, and the laborious task of source cleaning.

Video
Customer LC/MS/MS Spotlight: Professor Sabra Botch-Jones

The PerkinElmer QSight LC/MS/MS is used for many applications, including forensic toxicology.

Video

Webinars

LC-MS Tips & Tricks

In this presentation, prepare to learn all of the best practices for Liquid Chromatography Mass Spectrometry from consumables all the way to instrumentation and analysis. This talk is well-suited for all LC/MS applications including environmental testing

Webinars
What’s in Your Water? Monitoring Cyanotoxins in Drinking Water by LC-MS/MS

Growing environmental concern has led to stricter regulations of drinking water and water supplies over the past decade including routine monitoring and detection of cyanotoxins resulting from ever-growing algae blooms. This talk discusses the utiliza

Webinars
What’s in Your Water? Monitoring Pharmaceuticals and Personal Care Products in Drinking Water by LC-MS/MS

Pharmaceutical and personal care products (PPCPS) are an emerging environmental concern and include human and veterinary prescriptions, over-the-counter medications, sunscreens, lotions, soaps and insect repellents. In this webinar we demonstrate the a

Webinars
Conquering PFAS Compliance with Simplified Implementation and Robust LC/MS/MS Workflows

In this short webinar, PerkinElmer’s Environmental Leader, Tom Hey, discusses simplified PFAS method implementation with the comprehensive PerkinElmer LC/MS/MS workflow, featuring ready-to use consumables kits, reagents and software-driven compliance.

Webinars
Optimizing Workflow and Efficiency in the Analysis of Emerging Contaminants, Including PPCPs and PFAS

Emerging contaminants, including perfluoroalkyl surfactants (PFAS) and Pharmaceuticals and Personal Care Products (PPCPs), have garnered increasing interest in recent years as their bioaccumulative nature and endocrine disrupting potential have become..

Webinars
Complex Matrices: How the PerkinElmer QSight LC/MS/MS can help tackle the toughest samples

When it comes to analyzing environmental or food samples, including water, soil, cannabis or any solid matrices, labs need to meet stricter regulations that demand lower detection limits.

Webinars
What’s in your Water? Monitoring of PFAS in Drinking Water According to EPA Method 537.1

The US EAP Method 537.1 is used for the determination of selected PFASs in drinking water by solid phase extraction and liquid chromatography/tandem mass spectrometry. This talk discusses the utilization of the PerkinElmer QSight® Triple Quadrupole LC

Webinars