QSight LC/MS/MS System | PerkinElmer
PerkinElmer
check quantity

QSight LC/MS/MS System

More than ever, laboratories analyzing food and environmental samples are faced with evolving challenges with stricter regulations demanding lower detection limits and higher levels of productivity. Lab operations need to be optimized, without any compromise on analysis confidence and accuracy.

With the PerkinElmer QSight® Triple Quad LC/MS/MS labs can test for the most challenging samples with maximized uptime and confidence. The unique dual-source configuration enables high-throughput labs to collect data in two complementary modes, maximizing the output from a single injection. Combined with the StayClean technology dramatically reduced source cleaning and maintenance, translating into higher productivity and high ROI. Running on the PerkinElmer Simplicity 3Q Software, the PerkinElmer QSight Triple Quad LC/MS/MS is easy-to-learn and use and it is a complete solution streamlining the complete workflow, from validated method development to data reporting.

Part Number
Model Name
BC003844
QSight 420 LC/MS/MS
more
BC003382
QSight 220 LC/MS/MS
more
BC003383
QSight 210 LC/MS/MS
more
BC003265
QSight 110 LC/MS/MS
more
Request Technical Support

Please enter valid quantity

Please log in to add favorites.

NULL OR EMPTY CART

Overview

The QSight LC/MS/MS System provides the capability and confidence required to analyze the most complex food and environmental samples. With high level of sensitivity and throughput, laboratories can meet even the most stringent regulatory requirements rapidly, easily, and effectively

  • Sensitivity for the most demanding regulations
  • Easy-to-use with ready to implement methods
  • Patented flow-based technology that enables up to 15% more productivity
  • StayClean Source, self-cleaning design for maximum sensitivity and exceptional uptime
  • Laminar Flow Ion Guide for highly efficient field-free transmission, providing virtually no maintenance requirements
  • Dual Source technology gives you the capability to set ESI or APCI modes, with two independent probes for true multiplexing
  • Modular Simplicity 3Q Software to acquire, quantify, and report with flexible data viewing options and powerful remote diagnostics.
  • Different models available (QSight 110 LC/MS/MS, QSight 210 LC/MS/MS, QSight 220 LC/MS/MS, QSight 420 LC/MS/MS) addressing different levels of performance and efficiency required by different labs’ analysis needs.

Specifications

Model Name QSight 220 LC/MS/MS
Resources, Events & More
  • All

Application Note

A Comparison Between ESI and APCI Ionisation Modes

Changing the source on many an LC/MS/MS instrument from ESI to APCI, and vice versa, involves cooling the source, manual removal and installation of the new source, followed by heating of the new source to the operating temperature, resulting in low throughput for analyses utilizing both ESI and APC ...

PDF 726 KB
A Multiclass Multiresidue Method for Analysis of Veterinary Drugs in Chicken by UHPLC/MS/MS

Veterinary drugs are used in animal production to treat diseases, prevent infection and protect growth of animals, which helps provide quality marketplace. However the uncontrolled use may cause heavy human disease so regulatory agencies around the world have established maximum residue levels (MRLs ...

PDF 1 MB
A Single Cannabis Method to Meet California Pesticide and Mycotoxin Residues Regulatory Requirements

Testing for the levels of pesticide and mycotoxins in cannabis is important to ensure consumer safety and quality control. In this work, the PerkinElmer application development team analyzed all 66 pesticides (including very hydrophobic and chlorinated pesticides typically analyzed by GC-MS/MS) and ...

PDF 2 MB
Analysis of Acrylamide in Potato Chips by Isotopically Standard Addition UHPLC-MS/MS

Acrylamide is a probable carcinogen organic compound that is found in some foods that are cooked at elevated temperatures. It’s origins are due to the condensation of the amino acid asparagine and glucose as part of Maillard reaction. In 2002, Acrylamide was found to be present in french fries and b ...

PDF 1 MB
Analysis of Aflatoxins by UHPLC

Aflatoxin B1 is considered to be the most genotoxic of the mycotoxins, and, when ingested by cows, is converted to aflatoxin M1 which has been shown to cause liver cancer in certain animals.

PDF 1 MB
Analysis of Mycotoxins in Multi-Grain and Corn Cereals

Mycotoxins produced by fungi as toxic secondary metabolites, leave grains, maize and cereals particularly vulnerable. With this in mind, and considering that an estimated 25% of all crops show some signs of mycotoxin contamination, many countries have established regulatory guidelines for maximum my ...

PDF 991 KB
Analysis of Per- and Polyfluoroalkyl Substances by EPA Method 8327 Using the QSight 220 UHPLC/MS/MS

Per- and polyfluoroalkyl substances (PFAS) are man-made carbon-chain based compounds that have been widely used in commercial and industrial products such as fire-fighting foams, water proofing treatments for clothing and furniture, nonstick cookware, and paper. PFAS’ are thermally and chemically st ...

PDF 1 MB
Analysis of Target Pesticide Residues in Berries with LC/MS/MS Coupled with a QuEChERS Sample Prep

Analysis of target pesticide residues in berries using a unique laminar flow UHPLC-ESI-MS/MS

PDF 1 MB
Analysis of Water-Soluble Vitamins in Infant Formula by UHPLC-MS MS

Water-soluble vitamins (WSV), comprised primarily of the vitamin B complex, are essential ingredients in many foods, particularly in infant formulas. When analyzing fortified foods, this can be particularly challenging due to the wide range in concentration of vitamins, in keeping with daily allowan ...

PDF 1 MB
Determination of Aflatoxin M1 in Milk and Infant Formula by QSight LC-MS-MS

Aflatoxin B1 is often found in animal feeds such as corn, cottonseed cake, groundnut meal, and other agricultural commodities. When these contaminated feeds are ingested by milk-producing animals, such as cattle, aflatoxin B1 can be converted to aflatoxin M1 (a hydroxy derivate of aflatoxin B1) by o ...

PDF 949 KB
Determination of Coumarin in Electronic Cigarette Liquids by LC/MS/MS

Coumarin (1,2-benzopyrone) occurs as a natural component in some plants, and is utilized as a flavoring ingredient in some foods, tobaccos and cosmetic products. In recent years, coumarin has been added to electronic cigarette liquid nicotine solutions as a flavoring component, producing a complex f ...

PDF 2 MB
Determination of Mycotoxins in Cereals by LC/MS/MS with Online SPE

Mycotoxins are toxic secondary metabolites produced by fungi, and are capable of causing disease and death in both humans and animals. Sample preparation is a critical step in the successful analysis of mycotoxins in food matrices. The "dilute and shoot" approach is a quick and easy way to introduce ...

PDF 3 MB
Determination of Nitrosamine Impurities in Active Pharmaceutical Ingredient (API) Using QSight 220 LC-MS/MS

Nitrosamines are a well-known group of highly potent, mutagenic impurities formed by the reaction of secondary amines with nitrite under acidic conditions. The most probable nitrosamine impurities are NDMA, NDEA, NMBA, NDBA, NDIPA, NEIPA. Following the initial observance of nitrosamine impurities in ...

PDF 448 KB
Determination of Polycyclic Aromatic Hydrocarbons in Seafood by UHPLC- MS/MS

Polycyclic aromatic hydrocarbons (PAHs) can contaminate foods during smoking, heating, and drying processes that allow combustion products to come into direct contact with food. They can also enter food supply chains through contaminated air and water, and accumulate in various food chains. Regulati ...

PDF 1 MB
Determination of Sulfonamides in Honey

In apiculture, sulfonamides are the most commonly used antibiotics to treat American and European Foulbrood, a type of disease that infects bees. This application note demonstrates how QSight 200 System can provides a very sensitive and robust platform for the analysis of sulfonamides in honey.

PDF 1 MB
Determination of Sulfonamides in milk by Ultra-Performance Liquid Chromatography coupled with Tandem Mass Spectrometry (QSight™)

Antibiotics are used in dairy cattle for different treatments, but it leads to accumulation of these residues in milk. Presence of such residues in human food can be responsible for allergic reactions, toxic effects and develops resistant strains of bacteria. To protect consumers, regulatory agencie ...

PDF 579 KB
PDF 1 MB
Direct Analysis of Glyphosate and Similar Polar Pesticides in Oatmeal by UHPLC-MS/MS

Glyphosate is a very polar compound with high solubility in water and low solubility in most organic solvents and, as such, requires methods based on derivatization which are labor-intensive and time consuming. The present work shows a 12 minute LC-MS/MS method with an amino-based column to analyze ...

PDF 1 MB
Estimation of 136 pesticide residue in Black Pepper using QuEChERS extraction technique and QSight™ LC-MS/MS

It is very well known that Black pepper is a complex matrix that requires a proper extraction and clean-up method for interferences. In this study, a fast, sensitive and selective multi-residue method has been developed for analysis of over 136 pesticides in Pepper samples by coupling a modified QuE ...

PDF 1 MB
Fast and Targeted Analysis of Cell Culture Media Components using QSight LC/MS/MS

Quantitative analysis of cell culture media components is a critical step in upstream bioprocess development. A comprehensive and quantitative understanding of cellular metabolic components could lead to a greater understanding of the process impacts on cell growth, productivity, and product quality ...

PDF 1 MB
Free Amino Acid Analysis in Homogenized Tomato Using the QSight 220 LC/MS/MS

The free amino acid content of produce, such as tomatoes, has an impact on the nutritional value and flavor characteristics of the vegetable. In this application note, the efficient and effective transfer of a commercial laboratory's in-house method to a QSight 220 LC/MS/MS for amino acid determinat ...

PDF 1 MB
Improved Throughput for the Analysis of Perfluoroalkyl and Polyfluoroalkyl Substances in Drinking Water by EPA Method 533

Growing health concerns regarding Per- and polyfluoroalkyl substances (PFAS) and their prevalence in consumer goods and the environment indicates a critical need to perform existing and upcoming regulatory methods efficiently and reliably on commercially available instrumentation. The United States ...

PDF 1 MB
LC/MS/MS: Analysis of Alkylphenol Ethoxylates (APEO) And Alkylphenols (AP) In Textiles

Alkylphenol ethoxylates (APEOs) are common surfactants used in in industrial and consumer detergents and cleaners, as well plastics and many industrial applications. Nonylphenol ethoxylates (NPEOs) belong to the group of non-ionic surfactants and are of particular interest, as they tend to degrade t ...

PDF 2 MB
Multi-residue Analysis of Pesticides in Animal Feed Using the QSight LC/MS/MS

Pesticides are employed in the growing of crops to prevent damage from a number of pests and fungi. When crops are grown to produce feed for livestock, there is a potential for pesticides residues to remain on the feeding stuffs, posing a risk to the livestock ingesting them. Pesticide residues are ...

PDF 2 MB
Multi-residue Analytical Method for the Confirmation and Quantification of 500+ Pesticides in Fruit and Vegetables

Pesticides are utilized in a number of agricultural applications to prevent, destroy, or control harmful organisms or diseases, as well as protect plants or plant products during production, storage and transport. Although successful in these applications, pesticides can pose a risk when consumed by ...

PDF 3 MB
Multiclass-Multianalyte Method for Mycotoxin Testing in Foods Using Immunoaffinity Column Sample Clean-up with QSight LC/MS/MS

This work shows a reliable, sensitive and selective method for multi-mycotoxin determination in food samples using a PerkinElmer QSight 220 LC-MS/MS system. The method has been validated in eight different matrices and can be used in routine testing labs to meet regulatory requirements.

PDF 2 MB
Quantitation of Microcystins and Nodularin in Drinking Water Samples to Meet EPA Method 544 Requirements Using QSight LC/MS/MS

Cyanotoxins often exist intracellularly in cyanobacteria and are released into the water when cells die. Blooms caused by cyanobacteria can be harmful to the human health, animals, and the environment. Microcystin-LR (MC-LR) is one of the most common cyanotoxins and ingestion will cause negative hum ...

PDF 901 KB
Rapid Determination of Trace Amounts of Aniline and Its Derivatives by Direct Injection UHPLC/MS/MS

Aniline and aniline derivatives are widely used as raw materials and intermediates in the polymer, rubber, dye, pesticide and pharmaceutical industries. Unintended releases of aniliane or its derivatives into the environment pose a serious threat, with release possible during any stage of production ...

PDF 587 KB
Simultaneous Detection of Estrogenic and Progestogenic Hormones in Edible Bird's Nest

This application note presents a sensitive and reliable LC/MS/MS method using the PerkinElmer QSight

PDF 859 KB
Simultaneous Determination of Plant Growth Regulators in Bean Sprouts

A simple and sensitive method for the simultaneous determination of plant growth regulators

PDF 2 MB
“No Dilute” Just Shoot: Robustness of a QSight LC-ESI-MS/MS for Low Level Pesticide Residue Analysis in Wine

In this study, the QSight LC-MS/MS system was used to evaluate the potential of eliminating sample preparation for trace level pesticide analysis in a complex sample such as wine. We injected undiluted red and white wine samples into the mass spectrometer and studied reproducibility in analysis of t ...

PDF 962 KB

Article

Driving Lab Efficiency and Performance Acceleration with LC/MS/MS

The COVID-19 pandemic impacted industries, economies, and lives, and brought about the need for a new approach for contract testing laboratories working in different application fields. Considering the directions shaping the laboratory industry, this article revises trends that could be also applied ...

PDF 438 KB

Brochure

Complete Aflatoxin M1 Testing Solutions

For third party food testing labs or producers who want to conduct aflatoxin M1 analysis in dairy products, our automated aflatoxin M1 ELISA assay and QSight LC/MS/MS aflatoxin M1 analyzer provide sensitive, accurate, and fit for purpose screening and confirmative analysis solutions that you can use ...

PDF 3 MB
Comprehensive Forensic Analysis Solutions

This brochure provides a simple guide to the analytical solutions and supporting services we provide for forensics and toxicology laboratories. We know it's not as simple as it seems in the movies, on television, or in the latest potboiler: forensic science is an exacting science, driven by the twin ...

PDF 1 MB
Comprehensive Testing Solutions for Feed Millers

Feed milling today is a complex business, and agribusinesses both large and small need to balance the nutritional and safety needs of livestock with availability of raw ingredients and their seasonality and variability. Add to that the valuable supplementation and medication that millers supply, and ...

PDF 3 MB
PFAS Analysis Brochure

PerkinElmer offers a portfolio of high-performance solutions to optimize your laboratory workflow for PFAS analysis. Our robust and reliable LC/MS/MS systems along with high quality consumables and the industry’s most trusted service and application support network will deliver the throughput, produ ...

PDF 2 MB
QSight Triple Quadrupole LC/MS/MS

Whether you’re a lab manager or a bench chemist, you know firsthand how things are changing quickly in food and environmental analysis. And your lab needs to change to keep pace.

PDF 8 MB

Case Study

PFAS Monitoring: How One Scientist is Thinking Ahead for the Environment

Predicting the long-term impact some substances have on human health and the environment is extremely difficult and in some instances we only become aware of certain substances and chemicals’ toxic impact after they have been widely used. Recently, PFAS (per- and polyfluoroalkyl substances) have bec ...

PDF 341 KB

Ebook

What's in Your Water? PFAS Analysis Explained

Over the past decade, awareness and concern about Per- and Polyfluoroalkyl Substances (PFAS) has grown and led to more in-depth analysis of these compounds and the effects that they can have on human health. Due to their inert nature, PFASs are persistent organic pollutants and have been found to ac ...

PDF 1 MB

Poster

Infographic - Solutions for your Toxicology Lab

Infographic Poster showing the range of different analytical solutions for Toxicology Labs; from GC and LC, to ICP-MS and UV-Vis. Benchtop and floor standing chromatography, spectroscopy and thermal solutions for everyday robust and reliable analyses. FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC ...

PDF 460 KB

Product Note

QSight Simplicity 3Q Software Suite

Our modular Simplicity 3Q™ software is ideal for acquiring, quantifying and reporting

PDF 1 MB
QSight Triple Quadrupole LC/MS/MS Preparing Your Lab

Lab reequirements for QSight triple quad LC/MS/MS systems, including storage, suppleis, space, electrical, power, gas supply requirements

PDF 660 KB

Regulatory Compliance Certification

Product Certificate - QSight 210 & 220

Product Certificate for the QSight 210 & 220

PDF 159 KB

Technical Note

Ion Transmission Through a Quadrupole Ion Guide

Ion Transmission Through a Quadrupole Ion Guide Under the Combined Influence of Viscous Flow and RF

PDF 1 MB
Theoretical Studies of Swirling Flow and Heating Methods

Theoretical Studies of Swirling Flow and Heating Methods on Droplet Evaporation in a Heated Coaxial

PDF 503 KB