TGA 4000 | PerkinElmer
PerkinElmer
check quantity

TGA 4000 系统, 100-240V/50-60Hz

TGA 4000 炉体采用集约式陶瓷设计,温度控制准确度和精度更高。其陶瓷炉体耐化学腐蚀性优异,适用于多种活性气体气氛,可充分拓展您的研究领域。

货号 N5370210
Request Technical Support

请输入有效数量

请登录以添加收藏夹。

购物车为空

*Not available in all regions. Terms and Conditions apply. Warranty is void if the product is misused.

详细信息

典型TGA应用:

  • 样本波动率
  • 水分含量
  • 氧化稳定性
  • 分解温度
  • 炭黑含量
  • 稳定剂的性能
  • 灰分含量

 

特点与优势:

  • 高性能平衡和炉子的精度和精度
  • 顶部装载平衡,便于样品装载和卸载
  • 快速冷却,减少循环时间,提高生产效率
  • 集成质量流量控制器可扩展应用灵活性
  • 可选的45位自动进样器,用于无人值守操作
  • 易于使用的Pyris软件套件

规格

21 CFR Part 11兼容 Yes
最高温度 1000 °C
型号名称 TGA 4000
便携式 No
技术类型 Thermal Analysis
保修 1 year
重量 16.0 kg
资源
  • 所有

Ebook

棕榈油分析 — 从上游到下游的完整实验室解决方案

质量控制监控和测试是确保棕榈油质量的重要环节。质量控制参数用于判断棕榈油产品的质量,并可对其进行监控和测试,以确保棕榈油没有故意或意外掺假。

PDF 11 MB
TGA 8000 Thermogravimetric Analyzer Consumables & Supplies Reference Guide

We are the leader in high sensitivity thermal analysis instrumentation, providing the confidence to achieve fast, accurate, reproducible results. The TGA 8000™ incorporates PerkinElmer’s 75 years of continuous innovation and experience into its intelligent design. The TGA 8000’s design, optimal temp ...

PDF 950 KB

链接

Polymer Characterization with Dynamic Mechanical Analysis (DMA)

The presentation is designed to introduce scientists, engineers, or other professionals to basic principles, terminology, and advanced polymer characterization with Dynamic Mechanical Analysis (DMA).

链接

网络研讨会

Materials Analysis Challenges for Battery Recyclers

Watch now to help you drive the development of more circular input structures by finding the best laboratory analysis solutions for material reclaim and reuse.

网络研讨会
Innovate Better Batteries From Your Electrolyte Analysis

Third installment in our Battery Series - From Chemicals to Materials. Focus in on electrolytes to uncover useful technologies and techniques for characterization and degradation analysis to innovate better battery materials and components, increasing pe

网络研讨会

产品手册

Polymer Testing Solutions Brochure: Analysis from R&D to QA/QC

Innovation is the lifeblood of industrial polymer development – the push to improve materials or develop new ones infuses new life into the industry from R&D through to QA/QC. Manufacturers are continually challenged to ensure effective quality control and streamline processes while meeting stringen ...

PDF 2 MB

产品说明

聚合物回收利用套装

聚合物的回收利用是一个蓬勃发展的行业,许多曾经被作为废弃物填埋的瓶子和容器现在被回收利用为新的产品。由于聚合物存在互不相容的趋势,鉴别聚合物是聚对苯二甲酸乙二醇酯(PET)或聚乙烯(PE)而不是聚碳酸酯(PC)或聚苯乙烯(PS),这样的问题很重要。聚合物的化学鉴别可通过使用Spectrum Two傅里叶变换红外光谱仪与通用全反射(UATR)附件实现。

PDF 1 MB

单页

Complex Polymer Characterization Made Simple Ensemble Flyer

The polymer industry is made up of a diverse set of players, all facing similar challenges. Better characterization of materials and derivatives in the polymer value chain is vital to understand their thermal properties and suitability for use in a variety of applications. Faster product development ...

PDF 429 KB
Qualitative Analysis of Evolved Gases in Switchgrass by TG-GC/MS

The hyphenation of TG-GC/MS is a powerful tool for quality control, safety, and product development. This Flyer discusses the utility of PerkinElmer TG-GC/MS with an example application – the identification of specific organic acids evolved during TGA analysis of switchgrass.

PDF 267 KB

合规认证证书

Product Certificate - TGA 4000

Thermogravimetric Analyzer, Model TGA 4000, with or without autosampler, Model AS6000 or AS8000

PDF 559 KB

常见问题解答

Pyris Enhanced Security FAQ

The regulations of 21 CFR Part 11 cover overall system compliance and include administrative, procedural and technical elements. Software alone cannot be compliant without the development and implementation of the other elements. PerkinElmer’s Pyris™ Enhanced Security software for Thermal Analysis i ...

PDF 187 KB

应用文献

从TG-IR应用文献中了解增塑剂特性

热重力分析(TGA)是一项常见的技术,用以研究加热过程中的重量损失。它可定量准确地告诉你重量损失的百分比,但TGA却无法得知逸出气体的化学成分。将TGA与FT-IR相结合可对TGA逸出废气进行识别,能够更全面地了解材料特征。TG-IR联用技术已广泛应用于聚合物行业。本应用文献展示了如何结合TGA与FT-IR分析的优势,以得出更全面的材料特征。

PDF 1022 KB
聚合物应用纲要

塑料是当今全球使用量最多的材料之一。它们已广泛融入现代工业和商业生活方式,几乎对每类产品都做出了不可替代的重大贡献。

您将在本纲要中了解聚合物、塑料、橡胶和先进材料的广泛应用,以及这些应用如何简化您的工作并提升效率。

PDF 57 MB
Characterization of Electronic Materials Using Thermal Analysis

A valuable application of thermal analysis (TEA) is for the characterization of electronic materials and components, including printed circuit boards (PCB) and encapsulants. The key properties that TEA can help address are softening temperature or Tg, completeness of cure, degree of cure, rate of cu ...

PDF 1 MB
Characterization of Polymers using TGA Application Note

Thermogravimetric analysis (TGA) is one of the members of the family of thermal analysis techniques used to characterize a wide variety of materials. TGA provides complimentary and supplementary characterization information to the most commonly used thermal technique, Differential Scanning Calorimet ...

PDF 821 KB
Characterizing of Emissions from Open Burning of Electronic Waste using TG-GC-MS System

The objective of this study is to demonstrate the application of an analytical technique that integrates thermal analysis with gas chromatography and mass spectroscopy to identify and quantify toxic compounds emitted during the burning of electronics waste at different oxidizing conditions. The stud ...

PDF 567 KB
The TGA Noack Test for the Assessment of Engine Oil Volatility

Researchers in the automotive and petrochemical industries have studied the effects of oil volatility on engine emissions and oil consumption over the past decade. The standard test for assessing oil volatility has been the Noack and gas chromatographic techniques. The Noack test conditions are reco ...

PDF 1 MB
Characterization of Polymers using TGA

Thermogravimetric analysis (TGA) is one of the members of the family of thermal analysis techniques used to characterize a wide variety of materials. TGA provides complimentary and supplementary characterization iinformation to the most commonly used thermal technique, DSC.

PDF 813 KB
Characterization of Electronic Materials Using Thermal Analysis

Thermal analysis is valuable for the characterization of electronic materials and components, including printed circuit boards (PCB) and encapsulants. In the manufacture of printed circuit boards or flip-chip packaging, the issue of cure of the epoxy matrix and the dimensional characteristics of the ...

PDF 1 MB
Confirmation of the Presence of Styrene Butadiene Resin (SBR) Polymer in Drywall Primer

Building specifications for the interior wall finish require the application of a vapor barrier rated primer followed by the normal decorative paint/top coat. Some architects and developers of condominium housing projects have started using a rated vapor barrier primer/paint to replace the tradition ...

PDF 1 MB
A novel method (TG-IR) for the rapid determination of Total Petroleum Hydrocarbons (TPH) in soil

A gas chromatographic analysis of the extract can provide even greater sensitivity and more detailed compositional information, but further increases the time required for the analysis. Thermogravimetric analysis coupled to infrared spectroscopy (TG-IR) can provide detailed information about the amo ...

PDF 1 MB
Analysis of Polluted Soil by TG-IR Technique

One of the most challenging analytical problems with increasing importance is the possibility to analyze soil polluted by the dispersion of organic fluids which sometimes features particularly high boiling points. The current techniques used solvent extraction and headspace chromatographic analysis, ...

PDF 3 MB
Polymer-Blend Batch Consistency Achieved Through QA-Compliant TGA Characterization

This application note provides methodologies and results on TGA analysis of a range of polymeric material samples including printed circuit boards, toothbrush bristles, and plastic bottles. Thermogravimetric analysis (TGA) is one of the members of the family of thermal analysis techniques used to ch ...

PDF 1 MB

指南

联用技术纲要

PerkinElmer’s hyphenated solutions couple two or more instruments to greatly increase the power of analyses and save precious time by acquiring more information from a single run. The TGA 8000™ and STA systems coupled with FT-IR, MS, and/or GC/MS instruments represent the industry’s most complete an ...

PDF 7 MB
Evolved Gas Analysis - Hyphenated Technology Guide

The needs for polymer, pharmaceutical, chemicals, food and beverage, and environmental analyses are constantly changing due to innovation demands and regulation changes. Evolved Gas Analysis (EGA) solutions combine multiple analytical technologies to empower speed and advanced information acquisitio ...

PDF 3 MB
A Beginner's Guide to Thermogravimetric Analysis

The Thermogravimetric Analyzer (TGA) is an essential laboratory tool used for material characterization. TGA is used as a technique to characterize materials used in various environmental, food, pharmaceutical, and petrochemical applications. This booklet provides an introduction to the concepts of ...

PDF 1 MB

操作手册

PerkinElmer TGA 4000 Installation and Hardware Guide

The TGA 4000 Installation and Hardware Guide provides an overview of instructions for the safe and proper installation of TGA 4000.

PDF 1 MB

海报

臭氧前体系统

C2至C12挥发性有机臭氧前体化合物的分析,是对分析化学家提出的严苛技术挑战。大气中的低浓度,加上需要经常监测以评估日变化,这意味着在通过热解吸分析之前,需要经历样品的预浓缩步骤。虽然样品可以在现场收集并带回实验室,但远程、基于现场的分析可以减少数据周转时间,最大限度地减少样品采集硬件,允许VOCs的存在与否,与气相数据相关。在这一领域中,如对低分子量C2 VOCs进行低温冷却,它们可以被吸附在固体吸附剂上。

PDF 2 MB
聚合物和塑料的高端解决方案 海报

聚合物市场充斥着大量工业产品制造商,有着多种不同的处理工艺,但仍面临着类似的挑战。 如为了实现产品高质量并降低成本,在竞争中领先一步,他们面临着越来越大的压力。

PDF 2 MB
Advanced Solutions for Solar Cells Poster

Download this poster for an all-in-one view of how PerkinElmer instrumentation can answer the analytical needs of the solar market. From R&D of nanomaterials and advanced materials to solar cell component testing including aging and defect analysis - our UV/Vis, DSC, TGA, FT-IR and ICP systems help ...

PDF 1 MB

白皮书

Selection Criteria for Analytical Technologies that Meet Polymer Manufacture and Recycling Testing Needs

This white paper discusses what testing is required at each step in the polymer production lifecycle from R&D to manufacture to recycling. It explores the analytical technologies that will meet those testing needs, and important considerations to help you select the instrumentation that will provide ...

PDF 1 MB