The STA 6000 同步热分析仪可提供您可以依赖的性能,可靠性和生产力。
false false*Not available in all regions. Terms and Conditions apply. Warranty is void if the product is misused.
21 CFR Part 11兼容 | Yes |
---|---|
最高温度 | 1000 °C |
最低温度 | 15 °C |
型号名称 | STA 6000 |
便携式 | No |
技术类型 | Thermal Analysis |
质量控制监控和测试是确保棕榈油质量的重要环节。质量控制参数用于判断棕榈油产品的质量,并可对其进行监控和测试,以确保棕榈油没有故意或意外掺假。
Regulatory demands are rising not only for pharmaceutical but also for environmental, cosmetics and personal care, nutraceutical, food and chemical industries compelling them to dedicate significant time to ensure their instruments meet compliance standa
This nanometrology portfolio infographic poster gives you a 1-page overview of the instrumentation required by laboratories for the investigation of nanomaterials which are used to develop advanced materials in a range of applications.
The presentation is designed to introduce scientists, engineers, or other professionals to basic principles, terminology, and advanced polymer characterization with Dynamic Mechanical Analysis (DMA).
Watch now to help you drive the development of more circular input structures by finding the best laboratory analysis solutions for material reclaim and reuse.
Third installment in our Battery Series - From Chemicals to Materials. Focus in on electrolytes to uncover useful technologies and techniques for characterization and degradation analysis to innovate better battery materials and components, increasing pe
Innovation is the lifeblood of industrial polymer development – the push to improve materials or develop new ones infuses new life into the industry from R&D through to QA/QC. Manufacturers are continually challenged to ensure effective quality control and streamline processes while meeting stringen ...
Whether you need to characterize sample materials of pharmaceutical tablets or polymers, the STA 6000 offers you simultaneous measurement and analysis of weight change and heat flow.
The PerkinElmer range of Simultaneous Thermal Analyzers (STA), offers you real-time measurement and analysis of sample weight change and heat flow. With innovative sensor technology and compact furnace design, our STA instruments are ideally suited for both research and routine applications.
The hyphenation of TG-GC/MS is a powerful tool for quality control, safety, and product development. This Flyer discusses the utility of PerkinElmer TG-GC/MS with an example application – the identification of specific organic acids evolved during TGA analysis of switchgrass.
热重分析仪与质谱(TGA-MS)联用技术正是为了测试分析逸出气的定性研究,为样品测试提供完整的逸出气讯息。
STA 6000提供制药公司和其他用户追求的高效率、高样品通量。它将DSC和TGA两种热分析技术结合起来,事半功倍,给用户提供可重复的结果。
塑料是当今全球使用量最多的材料之一。它们已广泛融入现代工业和商业生活方式,几乎对每类产品都做出了不可替代的重大贡献。
您将在本纲要中了解聚合物、塑料、橡胶和先进材料的广泛应用,以及这些应用如何简化您的工作并提升效率。
Researchers in the automotive and petrochemical industries have studied the effects of oil volatility on engine emissions and oil consumption over the past decade. The standard test for assessing oil volatility has been the Noack and gas chromatographic techniques. The Noack test conditions are reco ...
In the “Early Drug Discovery Phase” of pharmaceutical development when there is a minimum amount of synthesized drug candidate, quick thermal analysis using a small amount of sample is the norm. The sample amount could be less than 3 mg. Because of the rush to identify possible drug candidates, anal ...
PerkinElmer’s hyphenated solutions couple two or more instruments to greatly increase the power of analyses and save precious time by acquiring more information from a single run. The TGA 8000™ and STA systems coupled with FT-IR, MS, and/or GC/MS instruments represent the industry’s most complete an ...
This guide offers an overview of analyses required throughout the battery value chain - learn about innovative analytical solutions for testing every part of the battery, including the anode, cathode, binder, separator, and electrolyte. See the value in data generated from a variety of applications ...
The Thermogravimetric Analyzer (TGA) is an essential laboratory tool used for material characterization. TGA is used as a technique to characterize materials used in various environmental, food, pharmaceutical, and petrochemical applications. This booklet provides an introduction to the concepts of ...
The needs for polymer, pharmaceutical, chemicals, food and beverage, and environmental analyses are constantly changing due to innovation demands and regulation changes. Evolved Gas Analysis (EGA) solutions combine multiple analytical technologies to empower speed and advanced information acquisitio ...
The STA 6000 Installation and Hardware Guide provides an overview of instructions for the safe and proper installation of STA 6000.
聚合物市场充斥着大量工业产品制造商,有着多种不同的处理工艺,但仍面临着类似的挑战。 如为了实现产品高质量并降低成本,在竞争中领先一步,他们面临着越来越大的压力。
This white paper discusses what testing is required at each step in the polymer production lifecycle from R&D to manufacture to recycling. It explores the analytical technologies that will meet those testing needs, and important considerations to help you select the instrumentation that will provide ...