Oxygenate and Aromatic Analyzers - Model 4086 | PerkinElmer
PerkinElmer
check quantity

Oxygenate and Aromatic Analyzers - Model 4086

Understanding the composition of finished gasoline is paramount to ensure that a safe and quality petroleum product is delivered to downstream oil and gas customers. PerkinElmer’s portfolio of oxygenate and aromatic analyzers are engineered specifically to meet the needs of customers producing finished gasoline products. Our analyzers can be used to determine ether and alcohol additives in finished gasoline products, as well as benzene, toluene, ethylbenzene and other aromatics as required. Trace methanol, acetaldehyde, MTBE, acetone, 2-propanol can also be analyzed in some models. Once installed, samples can be processed immediately, allowing you to optimize instrument up-time and productivity from day one.

货号
Type
检测方法
检测器类型
NARL6503
Model 4080
EN 12177, EN 13132 and IP 425/96
FID
更多
NARL8500
Model 4001
ASTM D4815
TCD
更多
NARL8501
Model 4002
ASTM D4815
FID
更多
NARL8410
Model 4015
ASTM D3608, ASTM D4815, ASTM D5580
FID
更多
NARL8511
Model 4012
ASTM D4815, ASTM D5580
TCD/FID
更多
NARL8503
Model 4004
ASTM D4815, ASTM D5580
FID
更多
NARL8512
Model 4013
D3606
TCD
更多
NARL8513
Model 4014
ASTM D3606
TCD
更多
NARL8528
Model 4080
EN 12177, EN 13132 and IP 425/96
TCD
更多
NARL8551
Model 4086
ASTM D7423 D7754 and UOP 960
FID
更多
NARL8504
Model 4005
ASTM D5580
FID
更多
Request Technical Support

请输入有效数量

请登录以添加收藏夹。

购物车为空

详细信息

Designed for the analysis of trace level oxygenated hydrocarbons (Acetaldehyde, MTBE, methanol, acetone, 2-propanol, DIPE, ETBE and TAME) in gasoline, liquefied petroleum gas and feed stocks of butenes, propylene, and naphtha contaminated with oxygenated compounds, Model 4086 guarantees detection levels of 0.5 ppm. The analyzer utilizes a PerkinElmer Clarus® 590 GC, and features a split/splitless injector, pressurized liquid valve, dual capillary column, Swafer microchannel flow technology and flame ionization detector (FID) to ensure precision and accuracy with ASTM D7423 D7754 and UOP 960. A capillary non-polar precolumn is utilized for separation of light nonpolar compounds and, in conjunction with the backflushing of heavy hydrocarbon utilizing a Swafer™ microchannel, Model 4086 ensures that high-boiling point material do not contaminate the main column.

规格

检测方法 ASTM D7423 D7754 and UOP 960
检测器类型 FID
型号兼容 Clarus 590 PPC
Type Model 4086
资源
  • 所有

应用文献

使用ASTM方法分析含氧化合物和芳香烃

Gasoline samples are complex and a single column solution is not always readily available for the required analysis. As such, solutions that have multiple columns, valves, backflushing and heartcutting ability have been developed to overcome these challenging separations. The resulting standardized ...

PDF 1 MB