UV/Vis Specialty Accessories | PerkinElmer
PerkinElmer

UV/Vis Specialty Accessories

The research Peltier range of accessories is ideal for any application that requires precise control of temperature at, below or above ambient temperature. The ability to operate up to 100 °C allows applications such as DNA melting, protein denaturation and some polymer studies to be performed.

产品与服务 (21)
Filters:

筛选条件

全部展开 全部折叠
产品类型
  • Accessories (12)
  • Consumables (9)
长度
温度-最高
温度-最低
产品组
  • Integrating Spheres & Supplies (1)
  • Peltier Accessories (5)
  • Reflectance Accessories (4)
  • Thermostatting Accessories (6)
  • Transmission Accessories (5)
体积

排序方式

1-21 的 21 产品与服务

  • PerkinElmer

    Water-Jacketed Single Cell Holder for LAMBDA 465

    This Water-Jacketed Single Cell Holder maintains temperature control for a standard 10 mm cell using recirculating liquid. Compatible with the LAMBDA 456 spectrometer. This holder requires, but does not include, a recirculating bath. PerkinElmer offers two baths (NB0080171 and N1015158), but this holder also works with locally-sourced baths.

  • Automatic Water Jacketed 8-Position Multi-Cell Holder for LAMBDA 465

    Water-Jacketed 8-Position Multi-Cell Changer For LAMBDA 465

    The Water-Jacketed 8-Position Multi-Cell changer automatically changes up to eight standard 10 mm cells. It is compatible with the LAMBDA 465 spectrometer. It requires, but does not include, a recirculating bath for sample temperature control. PerkinElmer offers two baths (B0080171 andN1915158). Locally sourced baths are also acceptable.
  • Film Holder for LAMBDA 365

    Transmission Holder for LAMBDA 365

    This Transmission Holder is compatible with the LAMBDA 365 spectrometer. It specializes in transmittance measurements of thin samples, such as film.

  • 50 mm Transmission/Reflectance Sphere, High Sensitivity for LAMBDA 365

    50 mm Transmission-Reflectance Sphere for the LAMBDA 365

    The high sensitivity 50 mm Transmission-Reflectance Sphere for the LAMBDA 365 has a port size of 10 mm and a recommended spectral bandwidth setting of 50 nm. This accessory comes with a White standard. Compatible with the LAMBDA 365.

  • Water-Jacketed Single Cell Holder for LAMBDA 365

    This Water-Jacketed Single Cell Holder maintains temperature control for a standard 10 mm cell using recirculating liquid. It requires, but does not include, a recirculating bath. PerkinElmer offers two baths (NB0080171 and N1015158), but this holder also works with locally-sourced baths. Compatible with the LAMBDA 365 spectrometer.
  • Water Jacketed 8-Position Multi-Cell Holder for LAMBDA 365

    Water-Jacketed 8-Position Multi-Cell Changer for LAMBDA 365

    The Water-Jacketed 8-Position Multi-Cell changer automatically changes up to eight standard 10 mm cells. It is compatible with the LAMBDA 365 spectrometer. It requires, but does not include, a recirculating bath for sample temperature control. PerkinElmer offers two baths (B0080171 andN1915158). Locally sourced baths are also acceptable.
  • Variable Angle Transmission Holder, 0-75° for LAMBDA 365

    Variable Transmission Holder for LAMBDA 365

    The Variable Angle Transmission Holder adjusts from 0° to 75°, providing a wide angle of incidence for your transmission measurements. It is compatible with the LAMBDA 365 spectrometer.
  • Advanced Transmission Holder for LAMBDA 365

    The Advanced Transmission Holder is designed to hold materials such as glass, polymers, and films. Its adjustable arms provide a positive locating point for samples, particularly thin samples such as films. Compatible with the LAMBDA 365 spectrometer.
  • PerkinElmer

    Spare Standard Mirror for the Relative Specular Reflectance Accessory

    The Spare Standard Mirror is an uncalibrated, flat mirror, approximately 40 mm square. It is used with the Relative Specular Reflectance Accessory 6° (B0086703) and the Variable Angle Reflectance Accessory (B0137314).

  • PerkinElmer

    T-Clip Adapter for 50 mm Transmission-Reflectance Sphere

    The T-Clip Adapter is an optional piece that allows the 50 mm Transmission-Reflectance Sphere (N4101011) to perform transmission measurements on films and other thin solid samples. With this part number, this clip can be ordered as a replacement or spare clip.
  • PerkinElmer

    Powder Cell Holder Kit for the 50 mm Transmission-Reflectance Sphere

    The Powder Cell Holder kit is used in the 50 mm Transmission-Reflectance Sphere to measure the reflectance of paste and powder samples. The kit includes a powder cell, two quartz windows for trapping light, and two quartz caps for the white standard.
  • Variable Angle Relative Specular Reflectance Accessory

    The Variable Angle Relative Specular Reflectance Sample Holder has a wavelength range of 175-3,300 nm and locates in the standard sample compartment of LAMBDA spectrometers. To use this accessory with the LAMBDA 365, you will need to use the Variable Angle Base Plate (N4101025).
  • PerkinElmer

    Temperature Measurement Kit

    The Temperature Measurement Kit supplies an in-cell temperature measuring probe for LAMBDA spectrometers. It includes a glass cell.

  • PerkinElmer

    Peltier Thermostatted Single Sample Holder

    The Single Sample Holder Accessory is a Research Peltier system. It is a single cell holder that provides temperature control for the sample position. It offers a selectable temperature range 20° to 45 °C. This accessory comes with a reference position cover, a power supply, power cables, and a user's guide.
  • Fixed Angle Reflectance Accessory

    Fixed Angle Reflectance Accessory - Fixed, 6°

    The Fixed Angle Reflectance Accessory enables reflectance or thickness measurements using a 6° fixed angle of incidence. It is compatible with the LAMBDA 25/35/45/650/750/800/850/850+/900/950/1050/1050+ spectrometers.

  • Research PeltierTM System - PTP-6

    The Research PeltierTM System (PTP-6) provides temperature control for six rectangular cells in the sample beam. It has a temperature range of 0° to 100°C.

  • PerkinElmer

    Powder Sample Holder for Relative Specular Reflectance Accessories

    The Powder Sample Holder for Relative Specular Reflectance Accessories includes the following powder-packing fixtures: a plunger, a press cylinder and cap, two 4.2 ml cups, and one 7.1 ml sample cup. Instructions are included.
  • PerkinElmer

    Single Sample Holder + Single Reference Holder

    The Single Sample Holder + Single Reference Holder is a Research Peltier System. It Includes the Single Sample Accessory (B2000159) for the sample position, and the Single Reference Accessory (B0510412) for the reference position. Selectable temperature range 20° to 45 °C.
  • PerkinElmer

    Peltier Thermostatted Reference Holder

    The Peltier Thermostatted Reference Holder is an optional single cell holder with a selectable temperature range of 20° to 45°C. It sits at the reference position of Peltier systems.
  • Peltier Controlled Fluid Circulator

    The Peltier Controlled Fluid Circulator has a temperature range of 20° to 60°C and an accuracy of +/-0.15ºC. It includes a serial port and documentation to enable PC programming. Also included is the Result Database Software (L6100050).
  • PerkinElmer

    Water-Thermostatted Reference Cell Holder

    The Water-Thermostatted Cell Holder is an auxiliary single cell reference position for standard 10 mm cells. It has 3 mm fluid tubing connectors to enable fluid- circulated temperature stabilization. It requires, but does not include, a fluid circulator.