增湿器 | PerkinElmer
PerkinElmer

增湿器

氩气增湿器常用于对包含极高浓度固溶物的样品进行ICP分析。氩气增湿器有助于避免盐类物质积聚在进样系统内,从而可使仪器连续运行且不需维护。

产品与服务 (10)
Filters:

筛选条件

全部展开 全部折叠
产品类型
  • Accessories (3)
  • Consumables (7)
长度
温度-最高
温度-最低
产品品牌名称
  • Capricorn (1)
  • Elegra (3)
  • pergo (6)
技术类型
  • ICP-MS (1)
  • ICP-OES (2)
体积

排序方式

1-10 的 10 产品与服务

  • Elegra_700x700

    Elegra Argon Humidifier for NexION 1000/2000

    This Elegra Argon Humidifier is for use with NexION® 1000 and 2000 ICP-MS series instruments. This Elegra Argon Humidifier features a compact and cost-effective design with a non-pressurized water reservoir. No heating or electric power required, and a direct connection to NexION 1000/2000 argon outlet is provided.
  • Elegra Dual Two-Channel Argon Humidifier for NexION 1000/2000

    Elegra Dual Two-Channel Argon Humidifier for NexION 1000/2000

    This Elegra Dual Two-Channel Argon Humidifier is for use with NexION® 1000 and 2000 ICP-MS series instruments. This Elegra Argon Humidifier features a compact and cost-effective design with a non-pressurized water reservoir. No heating or electric power required and direct connection to NexION 1000/2000 argon outlet provided.
  • pergo 2 Argon high solids accessory w/o Nebulizer

    pergo 2 Humidifier with MEINHARD Plus Type C Nebulizer

    The pergo 2 Argon Humidifier is for use with ELAN® and NexION® ICP-MS series instruments. The pergo improves performance of all concentric nebulizers for the routine analysis of brines, fusion digests and other high-TDS samples. A high pressure membrane positioned inside a temperature-controlled water reservoir perfuses water vapor into the ICP nebulizer gas stream. By increasing humidity in the argon nebulizer gas, the pergo prevents salt deposits at the nebulizer tip, improving short and long-term signal stability. The pergo 2 is designed for analyses dealing with high concentrations of dissolved solids on instruments using auxiliary gas.
  • pergo 2 Argon high solids accessory w/o Nebulizer

    pergo 1 Humidifier with PFA-ST Nebulizer

    The pergo 1 Argon Humidifier is for use with Optima®, Avio®, ELAN®, and NexION® series instruments. The pergo improves performance of all concentric nebulizers for the routine analysis of brines, fusion digests and other high-TDS samples. A high pressure membrane positioned inside a temperature-controlled water reservoir perfuses water vapor into the ICP nebulizer gas stream. By increasing humidity in the argon nebulizer gas, the pergo prevents salt deposits at the nebulizer tip, improving short and long-term signal stability. Includes gas line connector kit.
  • N8152692_pergo

    pergo 2 Gas Line Conversion Kit for NexION 1000/2000

    This pergo Gas Line Conversion Kit is for use with NexION® 1000 and 2000 ICP-MS series instruments. The pergo 1 Gas Line Conversion Kit (N8152683) is also available for NexION® 1000/2000.
  • N8152683_pergo

    pergo 1 Gas Line Conversion Kit for NexION 1000/2000

    This pergo Gas Line Conversion Kit is for use with NexION® 1000 and 2000 ICP-MS series instruments. The pergo 2 Gas Line Conversion Kit (N8152692) is also available for NexION® 1000/2000.
  • pergo 2 Argon high solids accessory w/o Nebulizer

    pergo 2 Humidifier without Nebulizer

    The pergo 2 Argon Humidifier is for use with ELAN® and NexION® ICP-MS series instruments. The pergo improves performance of all concentric nebulizers for the routine analysis of brines, fusion digests and other high-TDS samples. A high pressure membrane positioned inside a temperature-controlled water reservoir perfuses water vapor into the ICP nebulizer gas stream. By increasing humidity in the argon nebulizer gas, the pergo prevents salt deposits at the nebulizer tip, improving short and long-term signal stability. The pergo 2 is designed for analyses dealing with high concentrations of dissolved solids on instruments using auxiliary gas.
  • pergo 1 Humidifier without Nebulizer

    The pergo 1 Argon Humidifier is for use with Optima®, Avio®, ELAN®, and NexION® series instruments. The pergo improves performance of all concentric nebulizers for the routine analysis of brines, fusion digests and other high-TDS samples. A high pressure membrane positioned inside a temperature-controlled water reservoir perfuses water vapor into the ICP nebulizer gas stream. By increasing humidity in the argon nebulizer gas, the pergo prevents salt deposits at the nebulizer tip, improving short and long-term signal stability. Includes gas line connector kit.
  • Elegra

    Elegra Argon Humidifier

    This Elegra Argon Humidifier is for use with Optima® 2x00/4x00/5x00/7x00/8x00 and Avio® 200/500 ICP-OES series instruments. The Elegra Argon Humidifier helps to alleviate salt deposits in the nebulizer and torch injector, allowing uninterrupted and maintenance-free operation.
  • Capricorn Argon Humidifier with Bypass

    This Capricorn Argon Humidifier is for use with Optima® 2x00/4x00/5x00/7x00/8x00 and Avio® 200/500 ICP-OES series instruments. The Argon Humidifier is commonly used in ICP analyses of samples with very high concentrations of dissolved solids. Helping to prevent salt build-up inside the sample introduction system, the Argon Humidifier allows uninterrupted and maintenance-free operation.